RTTI- Reliance Technical Training Institute

Moore

Moore

 

 

prodex1

 

 

 

 

Moore 340 Pressure Transmitter-Controller
FEATURES & BENEFITS
Silicon-based MycroSENSORTM provides exceptional
performance
Rotatable NEMA 4X/6P, IP66/68 housing and rotatable
Smart Display (shown on the next page) deliver
long, trouble-free operation and maximum flexibility
in mounting options
SmartDisplay in engineering units affords greater operator
understanding
Fully interchangeable components (shown on the
next page) result in fewer spare parts and reduced
inventory costs
ABS/FM/CSA/CENELEC/SAA approvals ensure safe
operation in various high industrial stress environments
Built-in PID controller reduces hardware and wiring
per loop costs
10 segment characterizer linearizes non-linear flow
elements and valves
Built-in common x1/2, x3/2, or x5/2 transfer functions,
totalizer, and process alarms reduce the need for additional
loop components
Re-ranging in engineering units, such as GPM, delivers
easy configuration changes
The ability to make on-line zero calibration adjustments
without removing pressure simplifies maintenance
and calibrationsXTC Transmitters – Pressure
74 Moore Process Automation Solutions www.moore-solutions.com
Unique Features of the XTC
DESCRIPTION
XTC transmitter-controllers offer an integral PID controller
to deliver process sensing and control capabilities in a
single instrument and eliminate the need for a separate
controller to handle basic PID loops. Thus, using XTCs in
a control application reduces the number of necessary devices,
while minimizing wiring costs via a direct connection
from the transmitter to the final control element.
Additional proven features include the silicon-based dual
element capacitive pressure MycroSENSOR and the hermetically
sealed pressure capsule, which combine to deliver
high performance with minimal maintenance.
XTC models include differential gauge, absolute, and
flanged level differential pressure transmitters, which can
all be remotely re-ranged, calibrated, and configured via a
number of HARTTM devices. These include control systems,
panelboard instruments, and universal handhelds.
XTC accessories include the Moore XTC communicator,
a handheld configuration terminal, PC-based configuration
software, and remote diaphragm seals.
HXTC Transmitters – Pressure
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 75
MODELS
Model 340D Differential Pressure
Transmitter-Controller
Spans from 0.2″ H2
O to 450 PSID (0.05 to 3100
KPA)
Standard Hastelloy-C diaphragms and 316SS wetted
parts (Ranges D & F)
1/4″ NPTF or 1/2″ NPTF process connection
Suitable for DP, level, and flow applications
Model 340A/G Absolute or Gauge Pressure
10″ H2
O Abs to 450 PSIA (2.5 to 3100 KPA abs)
O to 5500 PSIG (2.5 to 37920 KPA)
Standard Hastelloy-C diaphragms and 316SS
wetted parts
1/2″ NPTF process connection
Suitable for pressure applications
Model 340F Flanged Level
O to 450 PSI (2.5 to 3100 KPA)
Standard 316SS diaphragms and wetted parts
Standard ANSI and DIN flanges
Suitable for level and flanged pressure applications
Model 340 Transmitter-Controller with
Sterling Output
0.035% of Reading Accuracy
Available in DP, GP, and flanged and level configurations
Suitable for HTG and other critical applicationsXTC Transmitters – Pressure
76 Moore Process Automation Solutions www.moore-solutions.com
PROCESS CONNECTIONS
Tantalum Diaphragms
Available in DP, GP, and AP configurations
Suitable for harsh process fluids
Remote Diaphragm Seals
Available in various materials and process connections
including threaded, flanged, weld-in, and
sanitary
Model 340D Differential Transmitter-Controller
with Integral Orifice Assemblies
Six integral orifice sizes
316 SS construction
“Wet” calibrations available
Suitable for low-flow applications
with Integral 3-Valve Manifold
Factory mounted
316SS or CS constructionXTC Transmitters – Pressure
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 77
SPECIFICATIONS
PERFORMANCE SPECIFICATIONS
Reference conditions: Zero-based, positive spans, ambient
temperature 23ºC, D/A trim values equal to span end
points, Silicone fill, standard diaphragms, 1 second damping.
Accuracy1,2
Analog Output
Range A:
±0.2% of calibrated span for spans from 1:1 to
2:1 of URL
±(0.174 + 0.013[URL/Span]) % of calibrated
span for spans from 2:1 to 25:1 of URL
Range B:
± 0.1% of calibrated span for spans from 1:1
to 2.5:1 of URL
± (0.043 + 0.0228 [URL/span]) % of calibrated
span for spans from 2.5:1 to 20:1 of
URL
Range D,F,G:
±0.1% of calibrated span for spans from 1:1 to
10:1 of URL
±(0.028 + 0.0072 [URL/span]) % calibrated
span for spans from 10:1 to 45:1 of URL
Digital Output
± 0.075% of Reading or 0.015% of URL,
whichever is greater
Sterling Units:
± 0.035 % of Reading or 0.006% of URL,
Ambient Temperature Effect
Models 340A, 340G, 340D
Ranges A-B:
±(0.175% URL + 0.075% span) per 28o
C
(50o
F)
Ranges D-G:
±(0.075% URL + 0.075% span) per 28o
Model 340F
Ranges D-F2
:
±(0.075% URL + 0.075% span + 1.5″ H2
O)
per 28º C (50ºF)
Temperature Limits
Sensor Assembly3
Silicon: -40 to 125ºC (-40 to 257ºF)
Inert Fill: 0 to 85ºC (32 to 185ºF)
Paratherm: -20 to 125ºC (-4 to 257ºF)
Electronics: -40 to 85ºC (-40 to 185ºF)
Stability
Zero Stability:
Range A: ±0.1% of URL for 6 months
Ranges B-G: ±0.1% of URL for 12 months
Span Stability: No Measurable Span Drift
Humidity
0-100% relative humidity, non-condensing
Vibration Effect
Less than ±0.05% of maximum span per G for 0 to
60 Hz in any axis up to 2 Gs max.
Power Supply Effect
Less than 0.005% of output span per volt
EMI/RFI Susceptibility
Less than 0.25% of max. span at 30 V/m,
30 MHz – 1 GHz
ESD Susceptibility
IEC severity level 4, 15 kV
Static Pressure Effect (340D)
Range Span Error Correctable To:4
B 0.2% per 100psi
D 0.2% per 1000psi
F 0.2% per 1000psi
NOTES:
(1) Accuracy includes the effects of linearity, hysteresis and repeatability.
(2) Specifications for 3″ & 4″ flange size only. For smaller flange
sizes, consult Moore.
(3) Limit to 85o
C (185o
F) in vacuum service.
(4) Zero effect eliminated at operating pressure.XTC Transmitters – Pressure
78 Moore Process Automation Solutions www.moore-solutions.com
Zero Elevation and Suppression
The range may be set anywhere between the LRL
and URL of the transmitter, as long as the
calibrated span does not exceed the minimum
allowable span (see Range table). Zero and
span in the XTC are non-interactive.
Electronic Damping (Digital Filter)
Adjustable between 0 and 30 seconds
Transmitter Outputs
Each transmitter has:
1. Analog, Two-Wire 4-20mA
2. Digital, HART Communications
3. Optional Transient Suppressor
Power Supply Requirements
Minimum Terminal to Terminal Compliance
Voltage: +10 Vdc
Maximum Terminal to Terminal Voltage: +42 Vdc
Maximum Load: RL = 50*(Supply Voltage)
– 500 Ohms1
FUNCTIONAL SPECIFICATIONS
Range and Sensor Limits
Model 340A, 340D, 340F, 340G
(1) To ensure digital communications, HART requires the loop
resistance to remain between 250 and 1100 Ohms. HART
also imposes the following requirements on the loop power
supply:
Ripple: 0.2 Vp-p, 47-125 Hz
Noise: 0.6 mV RMS maximum
Impedance: 10 Ohms maximum
(2) The Maximum Working Pressure (MWP) is defined as the
maximum pressure which can be applied to the cell without
damage, static or otherwise.
(3) 340D Range A and Range B sensors have a body rating of
+/- 4000 psi; however, no over pressure protection is employed
in these units thereby limiting the MWP to +/- 100
psi.
Maximum Working Pressure2
Range 340A 340D 340G 340F
A NA +/-60 psi3
(+/-413KPA) NA NA
B NA +/-100 psi3
(+/-689KPA) NA NA
D 250psi (1.72MPA) +/-4000 psi (+/-27.6MPA) 250 psi (1.72MPA) Per Flange
F 1500psi (10.3MPA) +/-4000 psi (+/-27.6MPA) 1500 psi (10.3MPA) Per Flange
G NA NA 9,000 psi(SS only 62.0MPA) NA
Range Min. LRL/URL
Span 340A 340D 340F 340G
A 0.20″ (.05KPA) NA -2/5″ (5/1.25KPA) NA NA
B 0.75″ (0.185KPA) NA -15/15″ (-3.7/3.7KPA) NA NA
D 10″ (2.5KPA) 0/450″ (0/112.5KPAabs) -450/450″ (-112.5/112.5KPA) -450/450″ (-112.5/112.5KPA) -407/450″ (-101/112.5KPA)
F 12.6psi (87KPA) 0/450psia (0/3045KPAabs) -150/450psi (-689/3100KPA) -150/450psi (-689/3100KPA) -14.7/450psig (-101/3100KPA)
G 300psi (2068KPA) NA NA NA 0/5500psig (0/37920KPA)
1 5 2 4
0
4 2
OPERATING
REGION
1 0
LOOP
RESISTANCE
(OHMS)
250
1600
700
POWER SUPPLY (Vdc)XTC Transmitters – Pressure
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 79
Surge Protection
(with optional Transient Suppressor)
Maximum clamping voltage (either loop terminal
to enclosure)
DC: 68V
100 kV per microsecond AC surge: 70V peak
1000 kV per microsecond AC surge: 120V peak
Transient surge current
Up to 5000 amp for 20 microseconds, repeated
strikes
Turn-On Time
The transmitter will begin operating within 5
seconds after power is applied. The transmitter
will perform within specifications
within 60 seconds after power is applied.
Local Indication
Optional 4 1/2 Digit SmartDisplay
MECHANICAL SPECIFICATIONS
Dimensions
See Installation Drawings (Pages 97-99)
Weight3
340A/G4
4 lbs
340D 7 lbs
340F 20 lbs
Electronics Housing
Epoxy Powder Coated, Low Copper Cast
Aluminum
316 SS (optional)
NEMA 4X/6P (IP66/68)
(2) 1/2″ -14 NPTF Electrical Conduit
Entrances (M20 x 1.5 optional)
Process Wetted Parts
Various Materials Available
NACE MR0175 compliant with options as noted in
the model number breakdown.
Flange Rating Process Connections
Model 340A/G5
(1) 1/2″ NPTF, no vent/drain (External block and
bleed may be purchased separately)
Model 340D
(2) 1/4″ NPTF with vent/drains
(1/2″ NPTF with optional process adapters)
High Pressure Side: Per flange size and rating
selected
Low Pressure Side: 1/4″ NPTF with vent/drain
(1/2″ NPTF with process adapter provided)
Hazardous Area Classification/Approvals6
Approved
ABS Type approved
FM/CSA Approval:
Intrinsically Safe:
Class I, Div. 1, Groups A, B, C, & D
Class II, Div. 1, Groups E, F, & G
Class III, Div. 1
Explosion Proof:
Class I, Div. 1, Groups B, C, & D
Non-Incendive:
Class I, Div. 2, Groups A, B, C, & D
CENELEC Approval:
Intrinsically Safe: EEx ia IIC T6, T5, T4
Explosion Proof: EEx d [ia] ia, IIC T47
BASEEFA Approval:
Non-Incendive: Exn IIC T6
SAA Approval:
Intrinsically Safe: Ex ia IIC T6
Explosion Proof: Ex d IIB T6
Non-Incendive: Ex n DIP IIC T6
(1) At 100ºF (38ºC), the rating decreases with increasing
temperature.
(2) At 120ºC, the rating decreases with increasing temperature.
(3) Weights approximate.
(4) 340A/G with tantalum diaphragm: 7 lbs.
(5) 340A/G Transmitters with tantalum diaphragms are
differential style units. Process connections are similar to
340D. See drawings.
(6) Consult Moore for information on additional approvals.
(7) Consult Moore for information on special power
requirements for EExd models.
Standard Class Carbon Steel Rating Stainless Steel Rating
ANSI 150# 285 psi1 275 psi1
ANSI 300# 740 psi1 720 psi1
DIN PN 10/16 16 bar2 16 bar2
DIN PN 25/40 40 bar2 40 bar2XTC Transmitters – Pressure
80 Moore Process Automation Solutions www.moore-solutions.com
MODEL NUMBER
Absolute Pressure
340A Absolute Pressure Transmitter-Controller
Input Range: Span Limits, Min/Max
D 10/450″ H2
O abs (2.5/112.5 KPA abs)
F 12.6/450 psia (87/3100 KPA abs)
Output
B 4-20 mAdc with HART Protocol1
C 4-20 mAdc with HART Protocol & Integral Transient Suppressor
D Direct Connection to Model 348 Field Mounted Controller or Spare Capsule
Process Diaphragm
H Hastelloy C-2761,3
S 316L SS
B Hastelloy C-276 with 1 Remote Seal (Specify AA for Body Parts)
Body Parts
Wetted Process Connection
AA 316SS 1/2″ NPT1
BA Hastelloy-C276 1/2″ NPT
Fill Fluid
B Silicone DC2001
C Inert
D Paratherm
Output Indicator
5 4-1/2 Digit Digital SmartDisplay
N Not Required5
Standard Options
X Oxygen Cleaned
Y Special Features4
Mounting Bracket
1 2″ Pipe Mount Bracket with SS Hardware
2 Universal Bracket
3 2″ Pipe Mount 316SS Bracket
Housing
1 Aluminum 1/2″ – 14 NPT1
2 Aluminum M20 x 1.56
3 316 SS 1/2″ – 14 NPT
4 316 SS M20 x 1.5
Hazardous Area Classification
2 CSA/CRN
3 FM/CSA All1
M CENELEC EEx d [ia] ia14
R SAA All & ABS Type Approved14
L CENELEC EExia & BASEEFA Ex N
N Non-Approved5
W FM/CSA All & ABS Type Approved
340AF B H AAB 5 N N 1 3 Sample Model Number
See notes on page 95.XTC Transmitters – Pressure
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 81
340D Differential Pressure Transmitter-Controller
A 0.2/5 “H2
O (0.05/1.25 KPA)10 (Remote seals not available with this range.)
B 0.75/15 “H2
O (0.185/3.7 KPA)2 (Matched remote seals only with this range.)
D 10/450 “H2
O (2.5/112.5 KPA)2
F 12.6/450 psi (87/3100 KPA)2
B 4-20 mAdc with HART Protocol1,2
H Hastelloy C-2762,3,8,11
S 316L SS2,7
A Hastelloy C-276 with 2 Remote Seals9,11
B Hastelloy C-276 with 1 Remote Seal on high side9,12
C Hastelloy C-276 with 1 Remote Seal on low side9,12
Wetted Vent/Drain Process Conn.
AA 316SS End 1/2 NPT1,2
AB 316SS Side (top) 1/2 NPT
AC 316SS Side (bottom) 1/2 NPT
AD 316SS Side (dual) 1/2 NPT
AE 316SS End 1/4 NPT
AF 316SS Side (top) 1/4 NPT
AG 316SS Side (bottom) 1/4 NPT
AH 316SS Side (dual) 1/4 NPT
BA Hastelloy C-276 End 1/2 NPT
BB Hastelloy C-276 Side (top) 1/2 NPT
BC Hastelloy C-276 Side (bottom) 1/2 NPT
BD Hastelloy C-276 Side (dual) 1/2 NPT
BE Hastelloy C-276 End 1/4 NPT
BF Hastelloy C-276 Side (top) 1/4 NPT
BG Hastelloy C-276 Side (bottom) 1/4 NPT
BH Hastelloy C-276 Side (dual) 1/4 NPT
RR Remote Seals
B Silicone DC2001,2
C Inert11
D Paratherm11
5 4-1/2 Digit Digital SmartDisplay 2
D B7M Bolts3
E B8M Bolts17
N Not Required2,5
1 2″ Pipe Mount Bracket with SS Hardware2
1 Aluminum 1/2″ – 14 NPT1,2
3 FM/CSA All1,2
R SAA All & ABS Type Approved
L CENELEC EExia & BASEEFA
N Non-Approved
Differential Pressure
340D D B H AA B 5 N 1 1 3 Sample Model Number
See notes on page 85.XTC Transmitters – Pressure
82 Moore Process Automation Solutions www.moore-solutions.com
340F Flanged Level Transmitter-Controller
Input Range: Span Limits, Min./Max.
High Side Dia/Wetted Low Side Dia/Wetted Extension Length
A0 316SS Hastelloy C-276/316SS Flush Mount1,2
A2 316SS Hastelloy C-276/316SS 2″15
A4 316SS Hastelloy C-276/316SS 4″15
A6 316SS Hastelloy C-276/316SS 6″15
B0 Hastelloy C-276 Hastelloy C-276/316SS Flush Mount
B2 Hastelloy C-276 Hastelloy C-276/316SS 2″15
B4 Hastelloy C-276 Hastelloy C-276/316SS 4″15
B6 Hastelloy C-276 Hastelloy C-276/316SS 6″15
C0 Monel Hastelloy C-276/316SS Flush Mount
C2 Monel Hastelloy C-276/316SS 2″15
C4 Monel Hastelloy C-276/316SS 4″15
C6 Monel Hastelloy C-276/316SS 6″15
D0 Tantalum Hastelloy C-276/316SS Flush Mount
G0 316SS Remote Seal Flush Mount
G2 316SS Remote Seal 2″15
G4 316SS Remote Seal 4″15
G6 316SS Remote Seal 6″15
Mounting Flange
Size Rating Material
A 2″ 150# CS
B 2″ 300# CS
C 3″ 150# CS2
D 3″ 300# CS
E 4″ 150# CS
F 4″ 300# CS
G 2″ 150# SS
H 2″ 300# SS
High Side Low Side
B Silicone DC200 Silicone DC2001,2
C Fluorolube Inert
D NEOBEE Paratherm
E Silicone DC550 Silicone DC200
F Silicone DC704 Silicone DC200
G Syltherm 800 Silicone DC200
5 4-1/2 Digit Digital Smart Display2
N Not Required
N Not Required2
4 316 SS M20-1.5
L CENELEC EExia & BASEEFA Type N
S 100mm 10/16 Bar CS
T 100mm 25/40 Bar CS
U 50mm 10/16 Bar SS
V 50mm 25/40 Bar SS
W 80mm 10/16 Bar SS
X 80mm 25/40 Bar SS
Y 100mm 10/16 Bar SS
Z 100mm 25/40 Bar SS
Flanged Level
High Side Low Side Extension
Dia/Wetted Dia/Wetted Length
H0 Hastelloy C-276 Remote Seal Flush Mount
H2 Hastelloy C-276 Remote Seal 2″15
H4 Hastelloy C-276 Remote Seal 4″15
H6 Hastelloy C-276 Remote Seal 6″15
J0 Monel Remote Seal Flush Mount
J2 Monel Remote Seal 2″15
J4 Monel Remote Seal 4″15
J6 Monel Remote Seal 6″15
K0 Tantalum Remote Seal Flush Mount
N0 Hastelloy C-276 Hastelloy C-276 Flush Mount
N2 Hastelloy C-276 Hastelloy C-276 2″15
N4 Hastelloy C-276 Hastelloy C-276 4″15
N6 Hastelloy C-276 Hastelloy C-276 6″15
Q0 Monel Hastelloy C-276 Flush Mount
Q2 Monel Hastelloy C-276 2″15
Q4 Monel Hastelloy C-276 4″15
Q6 Monel Hastelloy C-276 6″15
R0 Tantalum Hastelloy C-276 Flush Mount
340FD B A0 C B 5 N N 1 3 Sample Model Number
J 3″ 150# SS2
K 3″ 300# SS
L 4″ 150# SS
M 4″ 300# SS
N 50mm 10/16 Bar CS
P 50mm 25/40 Bar CS
Q 80mm 10/16 Bar CS
R 80mm 25/40 Bar CS
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 83
Gauge Pressure
340G Gauge Pressure Transmitter-Controller
F 12.6/450 psig (87/3100 KPA)2
G 300/5500 psig 2008/37920 KPA)2
H Hastelloy C-2761,2,3
Wetted Process Connection
AA 316SS 1/2″ NPT1,2
BA Hastelloy C-276 1/2″ NPT
5 4-1/2 Digit Digital SmartDisplay2
340G F B H AA B 5 N 1 1 3 Sample Model Number
84 Moore Process Automation Solutions www.moore-solutions.com
340 DD E H DA B 5 N N 1 3 Sample Model Number
Sterling High Performance
340 Sterling Performance Transmitter-Controller
Type and Input Range: Span Limits, Min/Max
DD Differential 10/450 “H2
O (2.5/112.5 KPA)
FD Flanged Level 10/450 “H2
GF Gauge 12.6/450 psi (87/3100 KPA)
E 4-20 mAdc High Performance Output with HART Protocol
H Hastelloy C-276
Wetted Process Conn. Type
DA 316SS 1/2″ NPT D
DB 316SS 1/4″ NPT D
GA 316SS 1/2″ NPT G
FA CS 2″, 150#, CS F
FB CS 2″, 300#, CS F
FC CS 3″, 150#, CS F
FD CS 3″, 300#, CS F
FE CS 4″, 150#, CS F
FF CS 4″, 300#, CS F
FG SS 2″, 150#, SS F
FH SS 2″, 300#, SS F
FI SS 3″, 150#, SS F
FJ SS 3″, 300#, SS F
FK SS 4″, 150#, SS F
FL SS 4″, 300#, SS F
5 4-1/2 Digit Digital Smart Display
2 UniversalBracket
3 FM/CSA All10
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 85
340 Absolute, Gauge & Differential Pressure Transmitter-Controllers with Tantalum Diaphragms
Type Span Limits, Min/Max.
Differential 10/450 “H2
Gauge 10/450 “H2
Gauge 12.6/450 psi (87/3100 KPA)
Absolute 10/450 “H2
O Abs (2.5/112.5 KPA)
Absolute 12.6/450 psia (87/3100 KPA)
Diaphragm
T Tantalum
Hi Side Lo Side Use with
TB Hastelloy-C 316SS A, G
TC Hastelloy-C Hastelloy-C D
TD Monel 316SS A, G1
TE Monel Monel D1
B Silicone DC200
C Inert13
N Not Required 5
D D
G D
G F
A D
A F
340 DB B T TE B N N N 1 3 Sample Model Number
(1) Standard for all ranges.
(2) Stock model selection.
(3) NACE MR0175 compliance requires this option.
(4) Please describe the modification or provide a quotation
reference number.
(5) Required selection for OUTPUT option “D”, direct connection
to the Moore 348.
(6) Not available with FM/CSA approvals.
(7) Standard on Input Ranges A & B.
(8) Standard on Input Ranges D & F.
(9) Must specify Body Parts code “RR”.
(10) Must select Body Parts “AA”.
(11) Not available with Input Range “A”.
(12) Not available with Input Range “A” or “B”.
(13) Available with Body Parts “TD” or “TE” only.
(14) CENELEC EExd & SAA units are only available with OUTPUT
code “B”.
(15) 2″ flanges with an extension or not available.
(16) 3″ and 4″ flanges with an extension will fit into Schedule 80
and larger i.d. pipes.
(17) B8M (316SS) bolting may have a reduced pressure rating.
Consult Moore for information.XTC Transmitters – Pressure
86 Moore Process Automation Solutions www.moore-solutions.com
MODEL DIFFERENCES &
MODIFICATIONS
If no range is selected, the instrument will be calibrated as
follows:
Range Code Default Calibration
A -0.5 to 0.5 “H2
O
B 0 to 10 “H2
D 0 to 100 “H2
O (or “H2
O abs)
F 0 to 100 PSI (or PSIA)
G 0 to 1000 PSIG
TRANSMITTER COMPONENTS
Common modifications can be specified by selecting a Y
in the Special Features category and describing the modification.
Always consult your salesperson before ordering
a modification.XTC Transmitters – Pressure
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 87
INSTALLATION DRAWINGS
Models 340A and Model 340GXTC Transmitters – Pressure
88 Moore Process Automation Solutions www.moore-solutions.com
Model 340D and Models 340A and 340G with Tantalum DiaphragmsXTC Transmitters – Pressure
Americas +1 215 646 7400 ext. 6613 Asia Pacific +65 299 6051 Europe +44 1935 706262 89
Model 340F Flange Mounted Transmitter
2″-150# 6.00 (152.40) 4.75 (120.65) 0.75 (19.05) 5/8 4 1.95 (49.53
2″-300# 6.50 (165.10) 5.00 (127.00) 0.88 (22.23) 5/8 8 1.95 (49.53)
3″-150# 7.50 (190.50) 6.00 (152.40) 0.94 (23.81) 0.06 (1.58) 5/8 4 2.81 (71.37)
3″-300# 8.25 (209.55) 6.625 (168.28) 1.13 (28.58) 3/4 8 ANSI B16.5 2.81 (71.37)
4″-150# 9.00 (228.60) 7.50 (190.50) 0.94 (23.81) 5/8 8 3.70 (93.98)
4″-300# 10.00 (254.00) 7.875 (200.03) 1.25 (31.75) 3/4 8 3.70 (93.98)
50MM-10/16 BAR 6.50 (165.00) 4.92 (125.00) 0.71 (18.00) M16 4
50MM-25/40 BAR 6.50 (165.00) 4.92 (125.00) 0.79 (20.00) M16 4
80MM-10/16 BAR 7.87 (200.00) 6.30 (160.00) 0.79 (20.00) 0.12 (3.00) M16 8 DIN 2526 Consult
80MM-25/40 BAR 7.87 (200.00) 6.30 (160.00) 0.94 (24.00) M16 8 TYPE C Moore
100MM-10/16 BAR 8.66 (220.00) 7.09 (180.00) 0.79 (20.00) M16 8
100MM-25/40 BAR 9.25 (235.00) 7.48 (190.00) 0.94 (24.00)
Product Description
MOORE XTC 340 PRESSURE TRANSMITTER CONTROLLER 340D2AH12 You are purchasing a Moore XTC Pressure Transmitter Controller. Model: 340D2AH12B5NN13 This Controller is in good condition and guaranteed fully operational. XTC transmitter-controllers offer an integral PID controller to deliver process sensing and control capabilities in a single instrument Digital Output Range D,F,G: ± 0.075% of Reading or 0.015% of URL, whichever is greater Sterling Units: ± 0.035 % of Reading or 0.006% of URL, whichever is greater Range: 10/450 IN H20 Shipping and handling is $14.90 in the USA. Very competitive rates for our always welcomed International bidders. – We always combine shipping to give you the lowest cost. – Contact us with any questions at 1-800-826-3433 (9-5pm Est) Please visit our other listings on ! Powered by 04.08.015

Leave a Comment

Your email address will not be published.